APC G55TUPSM30HB15S uninterruptible power supply (UPS) Double-conversion (Online) 30 kVA 27000 W
- Form factor: Large tower
- Product colour: Silver
- UPS topology: Double-conversion (Online)
- Output power capacity: 30 kVA
- Output power: 27000 W
- Manual
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
G55TUPSM30HB15S Features
- MGE Galaxy 5500 30KVA 400V Integrated Parallel UPS 15 Minutes, Start-up 5x8
- A versatile 3-phase UPS for facility, industrial and data center applications. Configurable system with a comprehensive range of accessories to meet your application demands.
- Includes: Installation guide, Network Management Card, Start-Up Service, User Manual
Documents
- ManualUser manual ↗
- ManualUser manual ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Large tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Silver
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 30 kVA
- Output powerThe power that the device can produce.
- 27000 W
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Quick installation guideIndicates whether a simplified, fast-start manual is included with the product.
- Yes
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
Show all 51 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Large tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Silver
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 30 kVA
- Output powerThe power that the device can produce.
- 27000 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 323 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 477 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 45/65 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 380 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 415 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 3
- Number of output phasesThe number of alternating current phases provided by the device to the connected load (e.g. 1 or 3).
- 3
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 92.4%
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 1
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 3:1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 2.5%
- Input current Total Harmonic Distortion (THD)The degree of harmonic distortion present in the input current, expressed as a percentage (%).
- 3%
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 712 mm
- DepthThe distance from the front to the back of something.
- 855 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1900 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 958 kg
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CE, EN/IEC 62040-3, IEC 62040-1-2, IEC 62040-2, ISO 9001, TUV, VDE
Packaging content
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Quick installation guideIndicates whether a simplified, fast-start manual is included with the product.
- Yes
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 1000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 12000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 14500 Ah
- Battery voltageThe voltage (V) of the battery.
- 432 V
- Battery life (max)Maximum battery life. Mobile Mark (2002) is the standard often used to benchmark battery life time.
- 10 year(s)
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 10 h
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- Hard Wire 4-wire (3PH + G), Hard Wire 4-wire (3PH + N)
- SmartSlotIndicates whether the unit features a dedicated expansion slot for installing optional network management or communication cards.
- Yes
Power
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 190 A
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload, Short circuit
Management features
- ECO modeIndicates whether the device features an energy-saving mode to reduce power consumption during operation.
- Yes
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 55.5 dB
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 980 mm
- Package depthThe distance from the front to the back of the packaging.
- 960 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 2030 mm
- Package weightWeight of the packaged product.
- 978 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC G55TUPSM30HS uninterruptible power supply (UPS) Double-conversion (Online) 30 kVA
27000 W
Specs & where to buy

APC G55TUPSM20HB30S uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA
18000 W 1 AC outlet(s)
Specs & where to buy

APC G55TUPSM40HB10S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA
36000 W 2 AC outlet(s)
Specs & where to buy

APC G55TUPSM20HB15S uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA
18000 W
Specs & where to buy

APC G55TUPSM40HS uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA
36000 W
Specs & where to buy

APC USV - 400 V uninterruptible power supply (UPS) Double-conversion (Online) 120 kVA
108000 W
Specs & where to buy