APC G3HT20KHLS uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA 16000 W 1 AC outlet(s)
- Form factor: Tower
- Product colour: Black, Grey
- UPS topology: Double-conversion (Online)
- Output power capacity: 20 kVA
- Output power: 16000 W
- Compliance certificates: RoHS
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Grey
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 20 kVA
- Output powerThe power that the device can produce.
- 16000 W
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 35 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -10 - 60 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
Show all 41 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Grey
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 20 kVA
- Output powerThe power that the device can produce.
- 16000 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 323 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 477 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 45/65 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 380 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 415 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
- Input power factorThe ratio of the real power drawn from the source to the apparent power supplied, indicating the efficiency of power delivery.
- 0.98
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 2.5:1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 5%
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 400 mm
- DepthThe distance from the front to the back of something.
- 950 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1300 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 130 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 61000-4-5, IEC 62040-2, TÜV, VFI-SS-111
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 35 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -10 - 60 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 9000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery voltageThe voltage (V) of the battery.
- 192 V
- Battery life (max)Maximum battery life. Mobile Mark (2002) is the standard often used to benchmark battery life time.
- 5 year(s)
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- Hard Wire 5-wire (3PH + N + G)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- Terminal
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 1 AC outlet(s)
Power
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 43 A
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 54.5 dB
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 800 mm
- Package depthThe distance from the front to the back of the packaging.
- 965 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 1440 mm
- Package weightWeight of the packaged product.
- 155 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC G3HT30KHB2S uninterruptible power supply (UPS) Double-conversion (Online) 30 kVA
24000 W 1 AC outlet(s)
Specs & where to buy

APC G3HT20KHB2S uninterruptible power supply (UPS) Double-conversion (Online) 20 kVA
16000 W 1 AC outlet(s)
Specs & where to buy

APC G3HT30KHB1S uninterruptible power supply (UPS) Double-conversion (Online) 30 kVA
24000 W
Specs & where to buy
APC G3HT15KHLS uninterruptible power supply (UPS)
Specs & where to buy

APC Smart-UPS uninterruptible power supply (UPS) Line-Interactive 1 kVA
700 W 8 AC outlet(s)
Specs & where to buy

APC G3HT40KHB1S uninterruptible power supply (UPS) Double-conversion (Online) 40 kVA
32000 W 1 AC outlet(s)
Specs & where to buy