APC Emergency lighting Galaxy 300
- Form factor: Tower
- Product colour: Grey
- UPS topology: Double-conversion (Online)
- Output power capacity: 30 kVA
- Output power: 14400 W
- Type of input protection required: gL fuse
All 46 specificationsProduct page at apc.com ↗
Versions
10 kVA · 6600 W · EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 61000-4-5, IEC 62040-2, TUV
10 kVA · 6600 W · EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 62040-2, TUV
15 kVA · 9600 W · CE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, TUV
15 kVA · 9600 W · EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 62040-2, TUV · 380 V · 19 A
15 kVA · 9600 W · EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 62040-2, TUV · 380 V · 24 A
20 kVA · 11600 W · CE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, EN61000-4-4, TUV · 220 V · 30 A
20 kVA · 11600 W · CE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, EN61000-4-4, TUV · 380 V · 30 A
20 kVA · 13300 W · CE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, EN61000-4-4, TUV · 220 V · 30 A
20 kVA · 13300 W · CE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, EN61000-4-4, TUV · 380 V · 30 A
30 kVA · 14400 W · CE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 61000-4-5, IEC 62040-2, TUV · 220 V · 48 A
30 kVA · 14400 W · CE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 61000-4-5, IEC 62040-2, TUV · 380 V · 47 A
30 kVA · 15600 W · CE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 61000-4-5, IEC 62040-2, TUV · 220 V · 48 A
30 kVA · 15600 W · CE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 61000-4-5, IEC 62040-2, TUV · 380 V · 47 A
30 kVA · 20000 W · CE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 61000-4-5, IEC 62040-2, TUV · 220 V · 48 A
30 kVA · 20000 W · CE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 61000-4-5, IEC 62040-2, TUV · 380 V · 47 A
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Wide input voltage range
Designed for harsh electrical environments to save battery life.
Industrial UPSFeatures & Benefits
Adaptability
Flexible Design
Available in a wide range of configurations to suit any operating environment
Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.
Multiple mounting methods
Allows for standardization on one product for use in different environments.
Availability
Cold-start capable
Provides temporary battery power when the utility power is out.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Wide input voltage range
Designed for harsh electrical environments to save battery life.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Manageability
LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
Optional Dry Contact I/O Accessory
Each Dry Contact I/O Accessory increases the number of input contacts by 2 and output relays by 1
SmartSlot
Customize UPS capabilities with management cards.
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Serviceability
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Technical support
Our experienced technical support engineers are available to answer your questions, giving you peace of mind knowing the help you need is there when you need it.
Documents
- BrochureProduct Brochure ↗
- ManualUser manual ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Grey
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 30 kVA
- Output powerThe power that the device can produce.
- 14400 W
- Type of input protection requiredThe specific electrical safety component needed to protect the input circuit, such as a 3-pole circuit breaker or gL fuse.
- gL fuse
- BypassSpecifies the method used to route power around the main circuitry to ensure continuous operation during maintenance or failure (e.g. Manual or Automatic).
- Built-in Maintenance Bypass
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 35 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -10 - 60 °C
Show all 46 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Tower
- Product colourThe colour e.g. red, blue, green, black, white.
- Grey
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Yes
- International Protection (IP) codeThe IP code classifies and rates the degree of protection provided against the intrusion (including body parts such as hands and fingers), dust, accidental contact, and water by mechanical casings and electrical enclosures. It is published by the International Electrotechnical Commission (IEC). The digits (characteristic numerals) indicate conformity with the conditions summarized in the tables b…
- IP20
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 30 kVA
- Output powerThe power that the device can produce.
- 14400 W
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 340 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 460 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 45/65 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 380 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 415 V
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 3
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 93%
- Crest factorThe ratio of the peak current to the average current of the load, expressed as a proportion (e.g., 3:1).
- 2.5:1
- Emergency Power Off (EPO)Indicates whether the unit features a remote connector to immediately shut down power in the event of an emergency.
- Yes
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 5%
Other features
- Type of input protection requiredThe specific electrical safety component needed to protect the input circuit, such as a 3-pole circuit breaker or gL fuse.
- gL fuse
- BypassSpecifies the method used to route power around the main circuitry to ensure continuous operation during maintenance or failure (e.g. Manual or Automatic).
- Built-in Maintenance Bypass
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 500 mm
- DepthThe distance from the front to the back of something.
- 860 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1300 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 200 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CE, EN/IEC 62040-1-1, EN/IEC 62040-2, EN/IEC 62040-3, IEC 61000-4-5, IEC 62040-2, TUV
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 35 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -10 - 60 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 9000 m
Display
- Display typeType of display (screen) e.g. LCD.
- LCD
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
Ports & interfaces
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- Terminal
- USB portThe device features a socket into which a USB cable can be plugged.
- Yes
- Serial interfaceIndicates whether the device features a serial port for communication and management purposes.
- Yes
- Serial interface typeThe physical connector standard used for the serial communication port (e.g. DB9 or RJ-45).
- RS-232
- Emergency Power Off (EPO) connectorIndicates whether the device has a dedicated port to remotely shut down the unit in the event of an emergency.
- Yes
- SmartSlotIndicates whether the unit features a dedicated expansion slot for installing optional network management or communication cards.
- Yes
Power
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 47 A
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 54.5 dB
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 800 mm
- Package depthThe distance from the front to the back of the packaging.
- 965 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 1440 mm
- Package weightWeight of the packaged product.
- 226 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC BX1000L-LM uninterruptible power supply (UPS) Line-Interactive 1 kVA
600 W 6 AC outlet(s)

APC Smart-UPS uninterruptible power supply (UPS) Double-conversion (Online) 3 kVA
2700 W 14 AC outlet(s)

APC BX800L-LM uninterruptible power supply (UPS) Line-Interactive 0.8 kVA
400 W 4 AC outlet(s)

APC Symmetra PX 48kW All-in-One, without Batteries, 400V

APC BX800LI-MS uninterruptible power supply (UPS) Line-Interactive 0.8 kVA
415 W

APC Galaxy 300 uninterruptible power supply (UPS) Double-conversion (Online) 80 kVA
64000 W