APC DIN Rail - Panel Mount UPS-without Battery-500VA 230V
- Form factor: Rackmount
- Product colour: Black
- UPS topology: Line-Interactive
- Output power capacity: 0.5 kVA
- Output power: 325 W
- Total carbon footprint (kg of CO2e): 441.6
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Proven Industrial UPS power protection for control applications and harsh environments.
Documents
- ManualUser manual ↗
- Documentbrochure ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 0.5 kVA
- Output powerThe power that the device can produce.
- 325 W
- Total carbon footprint (kg of CO2e)The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
- 441.6
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CE, VDE
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
Show all 36 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Line-Interactive
- Output power capacityThe maximum power that the device can produce.
- 0.5 kVA
- Output powerThe power that the device can produce.
- 325 W
- Input operation voltage (min)The minumum voltage needed by the device during operation.
- 151 V
- Input operation voltage (max)The maximum input voltage supported by the device.
- 302 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 47/53 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 220 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 240 V
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 540 J
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 94%
- Output voltage Total Harmonic Distortion (THD)The percentage of harmonic distortion present in the output voltage waveform compared to a pure sine wave.
- 5%
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
Carbon footprint
- Total carbon footprint (kg of CO2e)The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
- 441.6
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 362 mm
- DepthThe distance from the front to the back of something.
- 171 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 148 mm
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CE, VDE
Packaging content
- ManualIndicates whether a printed user manual is included in the package.
- Yes
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
Power
- Number of batteries supportedThe number of batteries that can be used with the product.
- 1
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- Hard Wire 5-wire (3PH + N + G)
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 0 AC outlet(s)
- RS-232 portsThe number of sockets (ports) for RS-232. An RS-232 serial port was once a standard feature of a personal computer, used for connections to modems, printers, mice, data storage, uninterruptible power supplies, and other peripheral devices. Now it has been largely replaced by USB and other ports.
- 1
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 55 dB
Logistics data
- Harmonized System (HS) codeThe standardized numerical method of classifying traded products used by customs authorities around the world to identify goods for tariffs and statistics.
- 85078000
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 297 mm
- Package depthThe distance from the front to the back of the packaging.
- 481 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 297 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC BR1350M2-LM uninterruptible power supply (UPS) Line-Interactive 1.35 kVA
810 W 10 AC outlet(s)
Specs & where to buy

APC BR1100M2-LM uninterruptible power supply (UPS) Line-Interactive 1.1 kVA
600 W 10 AC outlet(s)
Specs & where to buy

APC Galaxy VS UPS 100kW 400V for External Batteries, Start-up 5x8
Specs & where to buy

APC BR1500M2-LM uninterruptible power supply (UPS) 1.5 kVA
900 W 10 AC outlet(s)
Specs & where to buy

APC Galaxy VS UPS 30kW 400V for External Batteries, Start-up 5x8
Specs & where to buy

APC Easy UPS 3S 20 kVA 400 V 3:1 UPS for internal batteries
Specs & where to buy