APC Back-UPS Pro uninterruptible power supply (UPS) Line-Interactive 1.2 kVA 720 W 10 AC outlet(s)

APC Back-UPS Pro uninterruptible power supply (UPS) Line-Interactive 1.2 kVA 720 W 10 AC outlet(s)

  • Product colour: Black
  • UPS topology: Line-Interactive
  • Output power capacity: 1.2 kVA
  • Output power: 720 W
  • Battery type: APCRBC124
  • Nominal output voltage: 230 V

All 66 specificationsProduct page at apc.com ↗

Where to buy

We're not tracking prices for this product yet. Check current prices directly at:

We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more

About this product

The Back-UPS RS offers high performance protection for your business and office computer systems. It provides abundant battery backup power, allowing you to work through medium and extended length power outages. It also safeguards your equipment from damaging surges and spikes that travel along utility, phone and network lines. A distinguishing feature of the Back-UPS RS is automatic voltage regulation (AVR). AVR instantly adjusts both low and high voltages to safe levels, so you can work indefinitely during brownouts and overvoltage situations, saving the battery for power outages when you need it most. Award-winning shutdown software automatically powers down your computer system in the event of an extended power outage. Additional features like audible alarms, LED status indicators, user replaceable battery, push-button circuit breakers and plentiful outlets (including transformer-block spaced outlets) make the Back-UPS RS the perfect unit to protect your business' productivity from the constant threat of power problems and lost data.

Green mode: Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.

Audible alarms: Provide notification of changing flywheel conditions

Battery failure notification: Provides early-warning fault analysis on batteries enabling timely preventive maintenance

Power-saving outlets: Automatically cuts power to idle equipment to conserve electricity.

LCD display: Alpha-Numeric Display which displays system parameters and alarms.

Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment

Cold-start capable: Provides temporary battery power when the utility power is out.

Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Audible alarms: Provides notification of changing utility power and UPS conditions.

User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

USB connectivity: Provides management of the UPS via a USB port (not available on all models).

Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles.

Boost and Trim Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery

Automatic Voltage Regulation (AVR): Gives higher application availability by correcting low and high voltage conditions without using the battery.

Intelligent battery management: Maximizes battery performance, life, and reliability through intelligent, precision charging.

Building Wiring Fault Indicator: This LED informs users of potentially dangerous wiring problems in the wall circuit.

Adjustable voltage sensitivity: Provides the ability to adapt the Power Conditioner for optimal performance in specific power environments or generator applications.

Automatic Voltage Regulation (AVR): Automatically steps up low voltage and steps down high voltage to levels that are suitable for your equipment.

Battery fault detection: Monitors room and individual battery temperature changes for early detection of thermal runaway, shorted cells, open circuit, and bad battery.

Battery-protected and surge-only outlets: Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment.

Safety-agency approved: Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Power conditioning: Protects connected loads from surges, spikes, lightning, and other power disturbances.

Audible alarms: Provides notification of changing utility power and UPS conditions.

Automatic restart of loads after UPS shutdown: Automatically starts up the connected equipment upon the return of utility power.

Automatic self-test: Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Battery replacement without tools: Allows quick, easy battery replacement.

LED status indicators: Quickly understand unit and power status with visual indicators.

Cold-start capable: Provides temporary battery power when the utility power is out.

Hot-swappable batteries: Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Resettable circuit breakers: Enables a quick recovery from overload events.

Transformer-block spaced outlets: Protect equipment with input transformer blocks without blocking access to other receptacles.

User-replaceable batteries: Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Adjustable voltage sensitivity: Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.

Adjustable voltage-transfer points: Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.

Intelligent battery management: Micro-processor controlled battery charging and diagnostic testing ensures maximum battery life.

Documents

Specifications

Key specifications

Product colour
Black
UPS topology
Line-Interactive
Output power capacity
1.2 kVA
Output power
720 W
Battery type
APCRBC124
Nominal output voltage
230 V
Nominal input voltage
230 V
Networking features
10/100/1000 Base-T
Warranty card
Yes
Software CD
Yes
Show all 66 specifications

Design

Product colour
Black

Features

UPS topology
Line-Interactive
Output power capacity
1.2 kVA
Output power
720 W
Waveform
Sine
Input operation voltage (min)
156 V
Input operation voltage (max)
300 V
Input frequency
50/60 Hz
Output frequency regulation
50/60 Hz
Automatic Voltage Regulation (AVR)
Yes
Surge energy rating
441 J
Hold time (min)
10 ms
Hold time (max)
12 ms
Efficiency
98.8%
Crest factor
3:1
Surge protection
Yes
Surge protection features
Digital Subscriber Line (DSL), Fax, Modem, Network, Telephone
Audible alarm(s)
Yes
Audible alarm modes
Low battery alarm, Overload alarm

Power

Battery type
APCRBC124
Nominal input voltage
230 V

Other features

Nominal output voltage
230 V
Software CD
Yes

Network

Networking features
10/100/1000 Base-T

Packaging content

Packaging content
Qty 2- Detachable IEC Power Cord
Warranty card
Yes
Cables included
Phone (RJ-11), USB cable
Manual
Yes

Software

Bundled software
PowerChute Personal Edition

Weight & dimensions

Width
112 mm
Depth
380 mm
Height
301 mm
Weight
11.6 kg

Certificates

Compliance certificates
RoHS
Certification
A-tick, C-tick, CE, GOST, GS Mark, Telepermit, TUV, REACH, PEP, EOLI

Sustainability

Sustainability certificates
ENERGY STAR

Operational conditions

Operating temperature (T-T)
0 - 40 °C
Storage temperature (T-T)
-15 - 45 °C
Operating relative humidity (H-H)
0 - 95%
Storage relative humidity (H-H)
0 - 95%
Operating altitude
0 - 9000 m
Non-operating altitude
0 - 15000 m

Display

Display type
LCD

Battery

Battery technology
Sealed Lead Acid (VRLA)
Battery capacity
187 VAh
Typical backup time at full load
5.4 min
Typical backup time at half load
15.7 min
Battery life (max)
5 year(s)
Battery recharge time
8 h
Hot-swap battery
Yes
Automatic battery test
Yes
Cold start
Yes
Replacement battery cartridge
1

Ports & interfaces

AC outlet types
C13 coupler
Power plug
C14 coupler
AC outlets quantity
10 AC outlet(s)
Number of output IEC jumpers
2
USB port
Yes

Performance

Noise level
45 dB

Logistics data

Products per pallet
24 pc(s)
Harmonized System (HS) code
85078000
Products per master (outer) case
1 pc(s)

Packaging data

Package width
238 mm
Package depth
488 mm
Package height
387 mm
Package weight
13.2 kg

Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.

Expert reviews

  • –

    the-gadgeteer.com2010

    Buy one. That’s the review. Just buy this UPS. This device will save your computer’s butt. I know from personal experience. On Monday morning, May 10 about 4 am, another typical Indiana spring storm blew through my small Mayberry-esque town. A dea...

    +
    Where do I start? Reliable, Comes with Power Chute Software that allows proactive configuration, easy to download software, simple to monitor power supply coming into the machines. Simply put, this device does exactly what it says it will do.
    −
    What can I say? That it's black and boxy and heavy and bulky? It's designed to save expensive electronics from damage, not win beauty contests. That it's boxy and heavy are about the only bad things I can find to say about it and these aren't exactly deal breakers....
    Read the review at the-gadgeteer.com ↗

Price history (90 days, best daily price)

Price history is still being collected for this product — check back soon.

Alternative models