APC Back-UPS uninterruptible power supply (UPS) Standby (Offline) 0.325 kVA 185 W
- Form factor: Compact
- Product colour: Black
- UPS topology: Standby (Offline)
- Output power capacity: 0.325 kVA
- Output power: 185 W
- Compliance certificates: RoHS
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Audible alarms
Automatic self-test
Battery-protected and surge-only outlets
Cold-start capable
Dataline Surge Protection
Hot-swappable batteries
Lifetime data recovery warranty
Power conditioning
Resettable circuit breakers
Safety-agency approved
Transformer-block spaced outlets
USB connectivity
Documents
- BrochureProduct Brochure ↗
- ManualUser manual ↗
Specifications
Key specifications
- Form factorThe shape or design of the product.
- Compact
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Standby (Offline)
- Output power capacityThe maximum power that the device can produce.
- 0.325 kVA
- Output powerThe power that the device can produce.
- 185 W
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- PEP, EOLI, CE, EN 50091-1, EN 50091-2, GS Mark, NEMKO
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
Show all 48 specificationsShow key specifications only
Design
- Form factorThe shape or design of the product.
- Compact
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
- LED indicatorsThe specific status lights available on the unit to provide visual feedback on its current state or connectivity (e.g., AC input, ACT, or Access).
- Status
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Standby (Offline)
- Output power capacityThe maximum power that the device can produce.
- 0.325 kVA
- Output powerThe power that the device can produce.
- 185 W
- Cable lengthHow long the cable is.
- 1.83 m
- WaveformThe shape and characteristics of the electrical signal produced or measured by the device (e.g. Pure sine or Biphasic truncated exponential).
- Sine
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50 Hz
- Output frequency regulationThe range or precision within which the output frequency can be adjusted or maintained, measured in Hz.
- 47 - 63 Hz
- Surge energy ratingA surge protector is an appliance designed to protect electrical devices from voltage spikes. A surge protector attempts to limit the voltage supplied to an electric device by either blocking or by shorting to ground any unwanted voltages above a safe threshold. The surge energy rating is a measure of how much energy a surge protector can theoretically absorb in a single event, without failure.
- 310 J
- Hold time (min)The duration the device can maintain the output voltage and frequency during a transient power loss, measured in ms.
- 4 ms
- Hold time (max)The maximum duration the device can maintain the output power during a power failure before shutting down, measured in ms.
- 8 ms
- EfficiencyThe percentage of input energy that is converted into useful work or output, rather than being lost as heat or waste (e.g. 92%).
- 95.5%
- Surge protectionIndicates whether the device protects connected equipment from sudden voltage spikes.
- Yes
- Surge protection featuresSpecifies the types of communication and power lines protected against voltage spikes (e.g., Coax, Network, or Telephone).
- Digital Subscriber Line (DSL), Fax, Modem
- Audible alarm(s)Alarms that make a sound when they are activated (set off).
- Yes
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 360 mm
- DepthThe distance from the front to the back of something.
- 95 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 115 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 4 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- PEP, EOLI, CE, EN 50091-1, EN 50091-2, GS Mark, NEMKO
Packaging content
- ManualIndicates whether a printed user manual is included in the package.
- Yes
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -15 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
Battery
- Battery technologyThe type of battery in the device, e.g. nickel–cadmium (NiCd).
- Sealed Lead Acid (VRLA)
- Battery capacityA measure of the charge stored by the battery. Determined by the mass of active material contained in the battery.
- 43 VAh
- Typical backup time at full loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is fully loaded (100% of capacity).
- 1.1 min
- Typical backup time at half loadThe amount of time that a backup energy source (e.g. UPS - Uninterruptible Power Source) can power the device for, when the backup energy source is half-loaded (50% of capacity).
- 6.5 min
- Battery life (max)Maximum battery life. Mobile Mark (2002) is the standard often used to benchmark battery life time.
- 5 year(s)
- Battery recharge timeApproximate time required to recharge the battery from completely empty to completely full
- 24 h
- Automatic battery testIndicates whether the device automatically performs periodic tests to verify the health and charge level of the battery.
- Yes
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- Type F
- Number of type F outputsThe total number of power outlets of type F (Schuko) available on the device.
- 4
Power
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 4 A
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 45 dB
Logistics data
- Products per palletQuantity of a single product per pallet. If more than one product is packed per carton; this is the number of products (not number of cartons) per shipping pallet.
- 64 pc(s)
- Harmonized System (HS) codeThe standardized numerical method of classifying traded products used by customs authorities around the world to identify goods for tariffs and statistics.
- 85078000
- Products per master (outer) caseThe total quantity of individual units contained within a single master shipping case, measured in pc(s).
- 1 pc(s)
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 465 mm
- Package depthThe distance from the front to the back of the packaging.
- 116 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 153 mm
- Package weightWeight of the packaged product.
- 4.6 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC Symmetra PX 20kW uninterruptible power supply (UPS) 20 kVA
20000 W
Specs & where to buy

APC SUA750I uninterruptible power supply (UPS) 0.75 kVA
500 W
Specs & where to buy

APC Smart-UPS XL Modular 1500VA 230V uninterruptible power supply (UPS) 1.5 kVA
1425 W
Specs & where to buy

APC Back-UPS BK650EI - 650VA, 4x C13 output, USB
Specs & where to buy

APC SUM3000RMXLI2U uninterruptible power supply (UPS) 3 kVA
2850 W
Specs & where to buy

APC Smart-UPS 1000VA uninterruptible power supply (UPS) 1 kVA
650 W
Specs & where to buy