APC APDU9967 power distribution unit (PDU) 0U Black
- Operating temperature (T-T): -5 - 60 °C
- Storage temperature (T-T): -25 - 65 °C
- Operating relative humidity (H-H): 5 - 95%
- Storage relative humidity (H-H): 5 - 95%
- Operating altitude: 0 - 3048 m
- Non-operating altitude: 0 - 15240 m
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
With Industry leading reliability, manageability, and security, APC Switched Rack PDU's provide advanced load management plus on/off outlet level power cycling and sequencing control.
Documents
- ManualUser manual ↗
- BrochureProduct Brochure ↗
Specifications
Key specifications
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 60 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3048 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15240 m
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 48 A
- Block 1 output currentThe maximum electrical current that can be delivered by the first output block, measured in A.
- 60 A
Show all 34 specificationsShow key specifications only
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 111 mm
- DepthThe distance from the front to the back of something.
- 76 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1833 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 14.5 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 60 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3048 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15240 m
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 48 A
- Block 1 output currentThe maximum electrical current that can be delivered by the first output block, measured in A.
- 60 A
- Block 2 output currentThe maximum electrical current that can be delivered by the second output block, measured in A.
- 60 A
- Load capacityThe maximum apparent power that the device can safely handle, measured in VA.
- 17300 VA
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 60 A
- Maximum total current draw per phaseThe highest amount of electrical current that can be drawn from a single phase, measured in amperes.
- 48 A
- Power protection featuresFeatures that protect the device against power problems e.g. overload.
- Overload
- Maximum powerThe maximum power that can be put into or produced by the device.
- 17300 W
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 208 V
Features
- Output voltageThe electrical potential difference delivered by the device, typically expressed in volts (e.g. 24-48).
- 208 V
- Cable lengthHow long the cable is.
- 1.8 m
- TypeCharacteristics of the device.
- Single-phase
- Rack capacityThe spase that device fill in rack.
- 0U
Ports & interfaces
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- IEC 60309
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C15 coupler, C19 coupler, C21 coupler
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Switched
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Horizontal/Vertical
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Packaging data
- Package weightWeight of the packaged product.
- 20 kg
- Package widthThe distance from one side of the packaging to the other.
- 221 mm
- Package depthThe distance from the front to the back of the packaging.
- 112 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 2149 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC APDU9966 power distribution unit (PDU) 24 AC outlet(s) 0U Black
Specs & where to buy

APC Rack PDU 9000 Switched, ZeroU, 20A, 208V
(21) C13/C15 & (3) C19/C21, L620 Cord
Specs & where to buy

APC Rack PDU 9000 Switched, ZeroU, 11.5kW, 200-240V
(21) C13/C15 & (3) C19/C21
Specs & where to buy

APC APDU9981EU3 power distribution unit (PDU) 24 AC outlet(s) 0U Black
Specs & where to buy

APC EPDU1232SX3620 power distribution unit (PDU) 36 AC outlet(s) 0U Black
Specs & where to buy

APC APDU9953 power distribution unit (PDU) 24 AC outlet(s) 0U Black
Specs & where to buy