APC AP8981X633 power distribution unit (PDU) 24 AC outlet(s) 0U Black
- AC outlets quantity: 24 AC outlet(s)
- Cables included: AC
- Operating temperature (T-T): -5 - 45 °C
- Storage temperature (T-T): -25 - 65 °C
- Operating relative humidity (H-H): 5 - 95%
- Storage relative humidity (H-H): 5 - 95%
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
APC Switched Rack Power Distribution Units (PDUs) enable advanced, user-customizable power control and active monitoring. Remote outlet level controls allow power on/off functionality for power recycling to remotely reboot equipment and restrict unauthorized use of individual outlets. Power sequencing delays allow users to define the order in which to power up or down attached equipment. Avoid circuit overload during power recovery and extend uptime of critical equipment by prioritizing the load shedding. Current metering provides real-time remote monitoring of connected loads. Switched Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and low profile circuit breakers. User-defined alarms warn of potential circuit overloads before critical IT failures occur. Users can access, configure, and control Switched Rack PDUs through secure Web, SNMP, or Telnet Interfaces and is complimented by APC Centralized Management platforms using InfraStruxure Central, Capacity Manager and Change Manager.
Documents
- BrochureProduct Brochure ↗
Specifications
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 24 AC outlet(s)
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C19 coupler
Packaging content
- Cables includedSpecifies the types and quantities of connection cables provided with the product (e.g., 3.5 mm to 3.5 mm or SATA).
- AC
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 16 A
- Maximum powerThe maximum power that can be put into or produced by the device.
- 11000 W
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 400 V
Features
- Cable lengthHow long the cable is.
- 3.6 m
- Rack capacityThe spase that device fill in rack.
- 0U
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Switched
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Vertical
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC SRT005 power distribution unit (PDU) 5 AC outlet(s) Black, Blue, White

APC Rack PDU 2G, Metered, ZeroU, 22.0kW(32A), 230V
(30) C13 & (12) C19, 10ft Cord

APC AP8981X631 power distribution unit (PDU) 24 AC outlet(s) 0U Black

APC Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V
(21) C13 & (3) C19 Red Silk power distribution unit (PDU) 24 AC outlet(s) 0U

APC Actassi - 1U power distribution rail - 7 sockets 19P UK

APC Rack PDU 2G Metered by Outlet with Switching ZeroU 11.0kW 230V
(21) C13 & (3) C19 Blue Silk power distribution unit (PDU) 24 AC outlet(s) 0U