APC AP8865 power distribution unit (PDU) 44 AC outlet(s) 0U Black
- AC outlets quantity: 44 AC outlet(s)
- Total carbon footprint (kg of CO2e): 6416
- Manual
- Operating temperature (T-T): 5 - 60 °C
- Storage temperature (T-T): -25 - 65 °C
- Operating relative humidity (H-H): 5 - 95%
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Description
The APC Metered Rack PDU distributes reliable power within a rack through a single input and multiple output receptacles The AP8865 offers real-time remote monitoring of connected loads and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment The 0U PDU includes a NEMA L21-30P input plug with 1 83m (6ft) cord, (2) NEMA 5-20R, (36) IEC 60320 C13 and (6) IEC 60320 C19 output receptacles The PDU can operate in a maximum ambient air temperature of up to 60°C (140°F) at full load The Network Management Card provides enhanced cybersecurity with secured interfaces and modified password policy The rack PDU integrates with EcoStruxureTM IT through a Network Management Card and can be accessed and configured via Web, SNMP, and Command Line Interface User-interactive LCD interface details current, real power, voltage, and energy measurements for local user access Embedded log memory with historical reporting enables users to meter power usage, optimize energy usage, and plan for capacity The PDU's locking IEC outlets, when used with locking power cords reduce the probability of accidentally disconnecting cords and dropping loads The rack PDU supports daisy-chaining of up to 4 PDUs on a single IP address An environmental monitoring port is available for external temperature/humidity monitoring (sensor sold separately, model AP9335T or AP9335TH) The rack PDU comes with a standard two-year warranty
Documents
- ManualUser manual ↗
- BrochureProduct Brochure ↗
Specifications
Key specifications
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 44 AC outlet(s)
- Total carbon footprint (kg of CO2e)The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
- 6416
- ManualIndicates whether a printed user manual is included in the package.
- Yes
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 5 - 60 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15240 m
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CSA C22.2 No. 60950,UL 60950-1
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208 V
Show all 35 specificationsShow key specifications only
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 44 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- NEMA L21-30P
- AC outlet typesThe type of outlet for AC electricity.
- NEMA 5-20R, C13 coupler, C19 coupler
Carbon footprint
- Total carbon footprint (kg of CO2e)The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
- 6416
Packaging content
- ManualIndicates whether a printed user manual is included in the package.
- Yes
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 56 mm
- DepthThe distance from the front to the back of something.
- 46 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1791 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 7.56 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 5 - 60 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15240 m
Certificates
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- CSA C22.2 No. 60950,UL 60950-1
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 208 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 30 A
- Load capacityThe maximum apparent power that the device can safely handle, measured in VA.
- 8600 VA
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 30 A
- Maximum total current draw per phaseThe highest amount of electrical current that can be drawn from a single phase, measured in amperes.
- 30 A
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 208 V
- Output connectionsSpecifies the available ports and interfaces used to transmit signals or data from the device to external equipment.
- 36x IEC 320 C13 6x IEC 320 C19 2x NEMA 5-20R
Management features
- MonitoringSpecifies the parameters that the device can track and report, such as current, energy, or temperature.
- Power, Voltage, Energy
Features
- Cable lengthHow long the cable is.
- 1.82 m
- Rack capacityThe spase that device fill in rack.
- 0U
Performance
- Security algorithmsSecurity algorithms are used to provide authentication, cipher key generation, integrity and radio link privacy to users on mobile networks. The security algorithms supported are the ones that can be used with this product.
- SNMP
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Metered, Monitored
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Vertical
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Display
- DisplayThe description of display that can includes display type, resolution, size etc.
- LCD
Packaging data
- Package weightWeight of the packaged product.
- 9.2 kg
- Package widthThe distance from one side of the packaging to the other.
- 107 mm
- Package depthThe distance from the front to the back of the packaging.
- 162 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 200 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC AP8858NA3 power distribution unit (PDU) Black

APC AP8881 power distribution unit (PDU) 42 AC outlet(s) 0U Black

APC AP8861 power distribution unit (PDU) Black

APC AP8858EU3 power distribution unit (PDU) 20 AC outlet(s) 0U

APC AP8959EU3 power distribution unit (PDU) 24 AC outlet(s) 0U Black