APC AP8453 power distribution unit (PDU) 24 AC outlet(s) 0U Black
- AC outlets quantity: 24 AC outlet(s)
- Total carbon footprint (kg of CO2e): 5046.47
- Operating temperature (T-T): -5 - 45 °C
- Storage temperature (T-T): -25 - 65 °C
- Operating relative humidity (H-H): 5 - 95%
- Storage relative humidity (H-H): 5 - 95%
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
APC Metered-by-Outlet Rack PDUs offer resilient power distribution and actively measure, display, and log volts, amps, real power (kW) & energy (kWh) at the outlet level. This PDU offers LCD display, real-time remote monitoring and user-defined alarms to help prevent circuit overloads that can cause accidental power loss to critical equipment. Historical reporting enables users to monitor and optimize energy use, and plan for capacity on a granular level for things like customer power usage. This PDU can operate at up to 60 degrees Celsius and can be accessed, configured, and managed remotely via EcoStruxure IT, Web, SNMP and Command Line Interface. Power is supplied to the PDU at 220-240 volts via IEC 309 2P + E plug with a 3m (10 ft) cord while power comes out at 230 volts through (21) C13 and (3) C19 locking outlets. Daisy-chaining is supported to monitoring up to 4 PDUs from 1 IP address as well as a local USB port for easy local firmware updates. As a Green Premium product, this unit comes with a verified product environment profile, including carbon footprint, scope 3 emissions and end of life instructions.
Specifications
Key specifications
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 24 AC outlet(s)
- Total carbon footprint (kg of CO2e)The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
- 5046.47
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, VDE
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
Show all 33 specificationsShow key specifications only
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 24 AC outlet(s)
- Power plugA power plug is a 2 or 3 pinned device that is placed into an electrical socket in order to make an electrical connection.
- IEC309
- AC outlet typesThe type of outlet for AC electricity.
- C13 coupler, C19 coupler
Carbon footprint
- Total carbon footprint (kg of CO2e)The total mean carbon footprint value generated across various lifecycle stages (manufacturing, transportation / logistics, use and end of life) per unit (for one single product) i.e., measured in kilograms CO2e.
- 5046.47
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 56 mm
- DepthThe distance from the front to the back of something.
- 51 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1829 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 8.21 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 5 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 5 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- EN 55022 A, EN 55024, EN 61000-3-2, EN 61000-3-3, VDE
Power
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 32 A
- Load capacityThe maximum apparent power that the device can safely handle, measured in VA.
- 7680 VA
- Maximum input current per phaseThe highest amount of electrical current that can be safely drawn from a single phase, measured in amperes (e.g., 16A).
- 32 A
- Maximum total current draw per phaseThe highest amount of electrical current that can be drawn from a single phase, measured in amperes.
- 32 A
- Maximum powerThe maximum power that can be put into or produced by the device.
- 7680 W
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 230 V
Management features
- MonitoringSpecifies the parameters that the device can track and report, such as current, energy, or temperature.
- Current, Power, Voltage
Features
- Cable lengthHow long the cable is.
- 3.05 m
- TypeCharacteristics of the device.
- Single-phase
- Rack capacityThe spase that device fill in rack.
- 0U
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Metered, Metered-by-outlet
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Vertical
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Packaging data
- Package weightWeight of the packaged product.
- 10.5 kg
- Package widthThe distance from one side of the packaging to the other.
- 163 mm
- Package depthThe distance from the front to the back of the packaging.
- 117 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 2037 mm
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC Rack PDU 2G, Metered-by-Outlet, ZeroU, 11.0kW, 230V
(21) C13 & (3) C19

APC Rack PDU 2G power distribution unit (PDU) 30 AC outlet(s) Black

APC Rack PDU 2G, Metered-by-Outlet, ZeroU, 20A, 208V
(21) C13 & (3) C19

APC Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 100-240V
(21) C13 & (3) C19

APC Rack PDU 2G, Metered-by-Outlet, ZeroU, 5.7kW, 208V
(21) C13 & (3) C19

APC Rack PDU 2G, Metered-by-Outlet, ZeroU, 16A, 230V
(21) C13 & (3) C19
Accessories & compatible products

APC NetShelter SX Advanced Rack, High Strength, 48U, 2258H x
800W x 1295D mm, with Shock Package, Black

APC NetShelter SX Advanced Rack, High Strength, 52U, 2436H x
750W x 1295D mm, with Shock Package, Black

APC NetShelter SX Advanced Rack, High Strength, 52U, 2436H x
800W x 1295D mm, with Shock Package, Black

APC NetShelter SX Advanced Rack, High Strength, 48U, 2258H x
750W x 1295D mm, with Shock Package, Black

APC NetShelter SX Advanced Rack, High Strength, 48U, 2258H x
750W x 1470D mm, with Shock Package, Black

APC NetShelter SX Advanced Rack, High Strength, 52U, 2436H x
750W x 1470D mm, with Shock Package, Black