APC AP4450 power distribution unit (PDU) 10 AC outlet(s) 1U Black
- AC outlets quantity: 10 AC outlet(s)
- Operating temperature (T-T): -5 - 45 °C
- Storage temperature (T-T): -25 - 65 °C
- Operating relative humidity (H-H): 0 - 95%
- Storage relative humidity (H-H): 0 - 95%
- Operating altitude: 0 - 3000 m
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
Provides redundant rack mount power to single-corded equipment.
Includes : Mounting hardware , Rack Mounting brackets , Serial configuration cable
10 kAIC Overcurrent Protection
Provides protection in the event of a significant overcurrent event.
Command line interface
Offers simultaneous remote management access through Telnet and SSH
Current Monitoring
Monitors the aggregate current draw per power distribution unit.
Cyber security
A cyber-secure connection provides improved security for your infrastructure devices, and machine data forms the basis of operational insights and analytics, aimed at reducing equipment maintenance costs.
Flash Upgradeable
Quickly and easily upgrade firmware via network download for future product enhancements. Eliminates the need to replace products already installed in the field when new features are released. (Note: Networked units only)
Quick Transfer Rate
Transfer rate is within the industry standard and within the time power supplies will typically drop loads. The transfer of one power source to another is seamless to the connected equipment avoiding disruption of equipment performance.
Remote Management Capabilities
Full-featured network management interfaces that provide standards-based management via Web, SNMP, and Telnet. Allows users to access, configure, and manage units from remote locations to save valuable time. Associated with this feature is the ability to quickly and easily upgrade the firmware via network download to installed units for future product enhancements.
RoHS
Certifies that electronic devices don't contain hazardous metals and flame retardants
StruxureWare Data Center Expert compatible
Enables centralized management via StruxureWare Data Center Expert.
Specifications
Ports & interfaces
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 10 AC outlet(s)
- AC outlet typesThe type of outlet for AC electricity.
- NEMA 5–15R
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 44 mm
- DepthThe distance from the front to the back of something.
- 236 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 432 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 4.4 kg
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- -5 - 45 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -25 - 65 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 95%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3000 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15000 m
Power
- Nominal input voltageThe voltage which the manufacturer recommends that the device needs to operate normally.
- 100-120 V
- AC input frequencyThe range of alternating current frequencies the device can accept from the power source, measured in hertz (e.g., 45 - 65).
- 50 - 60 Hz
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 15 A
- Load capacityThe maximum apparent power that the device can safely handle, measured in VA.
- 1440 VA
- Maximum total current draw per phaseThe highest amount of electrical current that can be drawn from a single phase, measured in amperes.
- 15 A
Other features
- Nominal output voltageThe voltage which the manufacturer states that the device can produce.
- 100-120 V
Design
- PDU typesA power distribution unit (PDU) is a device fitted with multiple outputs designed to distribute electric power, especially to racks of computers and networking equipment located within the data center. PDUs vary from simple and inexpensive rack-mounted "power strips" to larger floor-mounted PDUs with multiple functions including power filtering to improve power quality, intelligent load balancing…
- Switched
- MountingWhat size the mounting head of the product is, to couple it with a camera.
- Horizontal
- Product colourThe colour e.g. red, blue, green, black, white.
- Black
Features
- Rack capacityThe spase that device fill in rack.
- 1U
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

APC AP4452 power distribution unit (PDU) 10 AC outlet(s) 1U Black

APC AP4434 power distribution unit (PDU) 9 AC outlet(s) 1U Black

APC AP4453 power distribution unit (PDU) 16 AC outlet(s) 2U Black

APC AP4433 power distribution unit (PDU) 12 AC outlet(s) 1U Black

APC PZ42I-GR power distribution unit (PDU) 4 AC outlet(s) Black