
APC ACRD101S rack cooling equipment Black 42U 929.7 l/s
- Housing colour: Black
- Input voltage: 100 - 240 V
- Input frequency: 50/60 Hz
- Number of input phases: 1
- Rack capacity: 42U
- Airflow: 929.7 l/s
Where to buy
We're not tracking prices for this product yet. Check current prices directly at:
We may earn a commission when you buy through links on this page — at no extra cost to you. Learn more
About this product
The InRow ACRD101S indoor direct expansion cooling unit efficiently removes heat from neighboring racks, providing cooling for low to medium heat density applications including network closets and small/medium data centers. The system has been optimized to use R32 low-GWP refrigerant. The small outdoor condensing unit (ACCU100) houses a variable capacity compressor and E-coated microchannel coil, enabling exceptional energy efficiency and corrosion resistance. This architecture also minimizes the indoor sound level, ideal for cooling IT equipment near office spaces. The InRow cooling system supports up to 120m (394ft) long and up to 30m (98ft) vertical piping between the indoor. And outdoor units maximizing installation flexibility. Additionally, the system provides reliable year-round operation from -15C/5F up to 46C/115F outdoor temperature and down to -40C/-40F with the optional low ambient kits. An optional, field-installed automatic transfer switch (ATS) increases cooling system resiliency by supporting redundant power feeds (indoor ACAC10059, outdoor ACAC10060). Four high-efficiency, variable speed EC axial fans ensure even air distribution across the heat exchanger. The unit can be purchased with factory-installed heaters and an electrode humidifier for complete temperature and humidity control (model ACRD101P). Internal and rack-mounted sensors allow the advanced controller to respond in real-time to environmental changes ensuring IT equipment receives the correct amount of air at the desired temperature. A containment-mounted pressure differential sensor (ACAC22000) is available to support different control methodologies. Multiple InRow units communicate with each other to maximize system efficiency, resiliency and temperature stability. The unit is remotely accessible via a variety of protocols, making it easy to integrate into BMS, DCIM and EPMS platforms. The ACRD101S delivers superior cooling efficiency, scalability and operational simplicity, helping to reduce energy use and maximize cooling system uptime.
Specifications
Design
- Housing colourThe colour of the housing, which is the rigid casing that encloses and protects a piece of moving or delicate equipment.
- Black
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 300 mm
- DepthThe distance from the front to the back of something.
- 1095 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 1991 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 150 kg
Power
- Input voltageThe voltage (V) which is required to power the product.
- 100 - 240 V
Features
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Number of input phasesThe number of alternating current (AC) power phases required for the input power supply (e.g. 1 or 3).
- 1
- Rack capacityThe spase that device fill in rack.
- 42U
Performance
- AirflowThe volume of air moved by the device per unit of time, measured in cubic metres per hour or cubic feet per minute.
- 929.7 l/s
Database Right data-sheet 2026 Icecat. All rights reserved. Provided “as is”, without warranty — check details with the store before buying.
Price history (90 days, best daily price)
Price history is still being collected for this product — check back soon.
Alternative models

Allied Telesis Hot swappable fan module

APC ACRH301S rack cooling equipment
930 W Black 42U 1374.3 l/s

Allied Telesis AT-CVFAN rack cooling equipment

APC Uniflair InRow Direct Expansion
300mm 30kW

Allied Telesis AT-SBXFAN12 rack cooling equipment

APC ACAC75016 rack cooling equipment
200 W Black 20 l/s Built-in display