CyberPower OL5KSTF uninterruptible power supply (UPS) Double-conversion (Online) 5 kVA 5000 W 12 AC outlet(s)
- Form factor: Rackmount
- Product colour: Black, Silver
- UPS topology: Double-conversion (Online)
- Output power capacity: 5 kVA
- Output power: 5000 W
- Compliance certificates: RoHS
Kde koupit
Ceny tohoto produktu zatím nesledujeme. Aktuální ceny najdete přímo v obchodech:
Když nakoupíte přes odkazy na této stránce, můžeme získat provizi — bez nákladů navíc pro vás. Více informací
O produktu
Converts 208V input voltage originating from utility power, a UPS, or a generator to 120V output
The CyberPower Smart App Online OL5KSTF rack/tower step-down isolation transformer converts utility power, UPS, or a generator input voltage ranging from 200 V to 240V to 120 V output.
The OL5KSTF has a capacity of 5,000 VA / 5,000 Watts. It features twelve (12) NEMA 5-20R receptacles that can support output to NEMA 5-15P and 5-20P plug power cords. Over temperature protection safeguards your OL5KSTF from damage if the internal heat exceeds safe operating parameters.
A Three-Year Warranty ensures that this transformer has passed our highest quality standards in design, assembly, material or workmanship.
Dokumenty
- BrožuraProduct Brochure ↗
Parametry
Hlavní parametry
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Silver
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 5 kVA
- Output powerThe power that the device can produce.
- 5000 W
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- UL1778 5th Ed. CSA C22.2 No.107.3-05 RoHS
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
Zobrazit všechny parametry (33)Zobrazit jen hlavní parametry
Design
- Form factorThe shape or design of the product.
- Rackmount
- Product colourThe colour e.g. red, blue, green, black, white.
- Black, Silver
- Housing materialWhat the casing of the product is made of.
- Metal
Features
- UPS topologyThe two main UPS topologies are Double-Conversion True Online and Standby / Eco. Many quality-based considerations are involved when choosing the the optimal UPS for the job, like how they are coping with voltage disturbances.
- Double-conversion (Online)
- Output power capacityThe maximum power that the device can produce.
- 5 kVA
- Output powerThe power that the device can produce.
- 5000 W
- Rack capacityThe spase that device fill in rack.
- 2U
- Cable lengthHow long the cable is.
- 0.9 m
- Input operation voltage (max)The maximum input voltage supported by the device.
- 208 V
- Input frequencyThe frequency (Hz) which is required to power the product.
- 50/60 Hz
- Output operation voltage (min)The minumum voltage produced by the device during operation.
- 120 V
- Output operation voltage (max)The maximum output voltage produced by the device.
- 208 V
- Output frequencyThe frequency of the electrical current delivered by the device, measured in hertz (e.g. 47/53 Hz).
- 50/60 Hz
Weight & dimensions
- WidthThe measurement or extent of something from side to side.
- 431.8 mm
- DepthThe distance from the front to the back of something.
- 599.4 mm
- HeightThe measurement of the product from head to foot or from base to top.
- 86.4 mm
- WeightWeight of the product without packaging (net weight). If possible, the net weight is given including standard accessories and supplies. Please note that sometimes the manufacturer leaves out the weight of accessories and/or supplies.
- 38 kg
Certificates
- Compliance certificatesIndicates which regulatory, safety, and environmental standards the product complies with, as verified by recognized authorities or certification bodies.
- RoHS
- CertificationSpecifies the official standards, safety approvals, or regulatory certifications the product has received.
- UL1778 5th Ed. CSA C22.2 No.107.3-05 RoHS
Operational conditions
- Operating temperature (T-T)The minimum and maximum temperatures at which the product can be safely operated.
- 0 - 40 °C
- Storage temperature (T-T)The minimum and maximum temperatures at which the product can be safely stored.
- -20 - 45 °C
- Operating relative humidity (H-H)The range of relative humidity, expressed as a percentage, within which the device can function correctly without damage or performance loss.
- 0 - 90%
- Storage relative humidity (H-H)The permissible range of relative humidity, expressed as a percentage, within which the product can be stored without damage.
- 0 - 95%
- Operating altitudeThe maximum and minimum height above sea level at which the device can function correctly, measured in m.
- 0 - 3048 m
- Non-operating altitudeThe maximum and minimum altitude at which the unit can be stored or transported without sustaining damage, measured in metres.
- 0 - 15239 m
Ports & interfaces
- AC outlet typesThe type of outlet for AC electricity.
- NEMA 5–20R
- AC outlets quantityThe number of sockets in the device where AC electrical power can be connected.
- 12 AC outlet(s)
Power
- Maximum currentThe greatest possible amount of current, which is a quantity representing the rate of flow of electric charge.
- 30 A
Performance
- Noise levelThe amplitude level of the undesired background noise, usually measured in decibels (db).
- 58 dB
Packaging data
- Package widthThe distance from one side of the packaging to the other.
- 599.4 mm
- Package depthThe distance from the front to the back of the packaging.
- 899.2 mm
- Package heightThe distance from the top to the bottom of the packaging.
- 330.2 mm
- Package weightWeight of the packaged product.
- 52.5 kg
Database Right data-sheet 2026 Icecat. All rights reserved. Poskytováno „tak, jak je“, bez záruky — před nákupem si podrobnosti ověřte v obchodě.
Historie cen (90 dní, nejlepší denní cena)
Historii cen tohoto produktu teprve sbíráme — podívejte se brzy znovu.
Alternativní modely

CyberPower CP1500PFCRM2U uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
1000 W 8 AC outlet(s)

CyberPower LCD HSTP3T10K uninterruptible power supply (UPS) Double-conversion (Online) 10 kVA
10000 W

CyberPower LCD CP1500AVRLCD3 uninterruptible power supply (UPS) Line-Interactive 1.5 kVA
900 W 12 AC outlet(s)

CyberPower OL2200ERTXL2U uninterruptible power supply (UPS) Double-conversion (Online) 2.2 kVA
2000 W 9 AC outlet(s)

CyberPower LCD Intelligent uninterruptible power supply (UPS) Line-Interactive 1.35 kVA
815 W 12 AC outlet(s)

CyberPower LCD CP1000AVRLCDa uninterruptible power supply (UPS) Line-Interactive 1 kVA
600 W 9 AC outlet(s)